For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
L-Proline tert-butyl ester
SpectraBase Compound ID ECXdRamhIYq
InChI InChI=1S/C9H17NO2/c1-9(2,3)12-8(11)7-5-4-6-10-7/h7,10H,4-6H2,1-3H3/t7-/m0/s1
InChIKey XJJBXZIKXFOMLP-ZETCQYMHSA-N
Mol Weight 171.24 g/mol
Molecular Formula C9H17NO2
Exact Mass 171.125929 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID EetdsQ8jpdE
Name L-Proline tert-butyl ester
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H63657
Lot Number S29D033
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1952
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 2812-46-6
Calibration Lamp Spectrum Correction.0
Container ID C-009994
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C9H17NO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C9H17NO2/c1-9(2,3)12-8(11)7-5-4-6-10-7/h7,10H,4-6H2,1-3H3/t7-/m0/s1
InChIKey XJJBXZIKXFOMLP-ZETCQYMHSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 171.240 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 62
Optical Filter Setting Open
Peak Amplitude 1949
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H63657-1G
SMILES N1[C@@](CCC1)(C(OC(C)(C)C)=O)[H]
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms (S)-tert-Butyl pyrrolidine-2-carboxylate
Technique FT-Raman
Zero Filling Factor 4