SpectraBase Spectrum ID |
EVmKfnva13s |
Name |
Nα-(9H-Fluoren-9-ylmethoxycarbonylamino)-Nω-(4-methoxy-2,3,6-trimethylphenylsulfonyl)-D-arginine |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H66194 |
Lot Number |
81400736 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270556 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-9680 |
Backward Peak Location |
14449 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
120075-24-3 |
Container ID |
C-009308 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C31H36N4O7S |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C31H36N4O7S/c1-18-16-27(41-4)19(2)20(3)28(18)43(39,40)35-30(32)33-15-9-14-26(29(36)37)34-31(38)42-17-25-23-12-7-5-10-21(23)22-11-6-8-13-24(22)25/h5-8,10-13,16,25-26H,9,14-15,17H2,1-4H3,(H,34,38)(H,36,37)(H3,32,33,35)/t26-/m1/s1 |
InChIKey |
LKGHIEITYHYVED-AREMUKBSSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
608.710 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-9737 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14506 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
95% |
Relative Humidity Interferometer |
20 % |
Resolution |
2 |
SKU |
H66194-1G |
SMILES |
N(C(OCC1c2ccccc2-c2ccccc12)=O)[C@](CCCNC(NS(=O)(=O)c1c(cc(c(c1C)C)OC)C)=N)(C(O)=O)[H] |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Sample Storage Requirements |
2-8°C |
Scan Time |
50.04 s |
Scanner Temperature |
28.8 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Technique |
KBr0 |
Zero Filling Factor |
8 |