SpectraBase Spectrum ID |
EVGjfUh4GYM |
Name |
Nδ-tert-Butyloxycarbonyl-Nα-(9-fluorenylmethyloxycarbonyl)-L-ornithine |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H62814 |
Lot Number |
5011R14N |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
2453 |
Backward Peak Location |
28691 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
109425-55-0 |
Calibration Lamp Spectrum |
Correction.0 |
Container ID |
C-010025 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C25H30N2O6 |
Frequency of First Point |
3597.79 cm⁻¹ |
Frequency of Last Point |
-1.31092 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C25H30N2O6/c1-25(2,3)33-23(30)26-14-8-13-21(22(28)29)27-24(31)32-15-20-18-11-6-4-9-16(18)17-10-5-7-12-19(17)20/h4-7,9-12,20-21H,8,13-15H2,1-3H3,(H,26,30)(H,27,31)(H,28,29)/t21-/m0/s1 |
InChIKey |
JOOIZTMAHNLNHE-NRFANRHFSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Molecular Weight |
454.523 g/mol |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
186 |
Optical Filter Setting |
Open |
Peak Amplitude |
-2313 |
Peak Location |
28689 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
96% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
H62814-1G |
SMILES |
N(C(OC(C)(C)C)=O)CCC[C@@](C(O)=O)(NC(OCC1c2ccccc2-c2ccccc12)=O)[H] |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
(S)-2-Amino-5-(benzyloxycarbonylamino)pentanoic acid |
Technique |
FT-Raman |
Zero Filling Factor |
4 |