2-METHYL-4-AMINOBUTANOL
SpectraBase Compound ID 9LEpVh43uAv
InChI InChI=1S/C5H13NO/c1-5(4-7)2-3-6/h5,7H,2-4,6H2,1H3/t5-/m1/s1
InChIKey DUAXLVGFFDFSAG-RXMQYKEDSA-N
Mol Weight 103.16 g/mol
Molecular Formula C5H13NO
Exact Mass 103.099714 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID ESEWZNexcy1
Name (R)-4-Amino-2-methyl-1-butanol
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A1576
Lot Number XX109-HOLF
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270461
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 16
Background Scans or Time Scans
Backward Peak Amplitude -8947
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 88390-32-3
Color Properties Colorless
Container ID C-009467
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C5H13NO
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C5H13NO/c1-5(4-7)2-3-6/h5,7H,2-4,6H2,1H3/t5-/m1/s1
InChIKey DUAXLVGFFDFSAG-RXMQYKEDSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 103.165 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 16
Optical Filter Setting Open
Peak Amplitude -8740
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 2
SKU A1576-1G
SMILES NCC[C@](CO)(C)[H]
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 24.995 s
Scanner Temperature 29.7 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8