For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4-Fluoro-4'-(trans-4-propylcyclohexyl)biphenyl
SpectraBase Compound ID iae2BYrcJj
InChI InChI=1S/C21H25F/c1-2-3-16-4-6-17(7-5-16)18-8-10-19(11-9-18)20-12-14-21(22)15-13-20/h8-17H,2-7H2,1H3/t16-,17-
InChIKey DYBQDZYHNOGWIK-QAQDUYKDSA-N
Mol Weight 296.43 g/mol
Molecular Formula C21H25F
Exact Mass 296.194029 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID ELsyNbVs6Xo
Name 4-Fluoro-4'-(trans-4-propylcyclohexyl)biphenyl
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number F1103
Lot Number YVQD-SI
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1914
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 87260-24-0
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009410
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C21H25F
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C21H25F/c1-2-3-16-4-6-17(7-5-16)18-8-10-19(11-9-18)20-12-14-21(22)15-13-20/h8-17H,2-7H2,1H3/t16-,17-
InChIKey DYBQDZYHNOGWIK-QAQDUYKDSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 242
Optical Filter Setting Open
Peak Amplitude 1888
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU F1103-1G
SMILES c1c(ccc(c1)[C@@]1(CC[C@](CC1)(CCC)[H])[H])-c1ccc(cc1)F
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 1-Fluoro-4-[4-(trans-4-propylcyclohexyl)phenyl]benzene
Technique FT-Raman
Zero Filling Factor 4