For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-Fluoro-benzenesulfonamide
SpectraBase Compound ID 8bh62HBZUNm
InChI InChI=1S/C6H6FNO2S/c7-5-2-1-3-6(4-5)11(8,9)10/h1-4H,(H2,8,9,10)
InChIKey CRINBBOGNYCAOV-UHFFFAOYSA-N
Mol Weight 175.18 g/mol
Molecular Formula C6H6FNO2S
Exact Mass 175.010328 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID Dy9mqFA0ARU
Name 3-Fluorobenzenesulfonamide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number F1141
Lot Number MX3GH-NF
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1584
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 1524-40-9
Calibration Lamp Spectrum Correction.0
Color Properties White-pale yellow
Container ID C-009714
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C6H6FNO2S
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C6H6FNO2S/c7-5-2-1-3-6(4-5)11(8,9)10/h1-4H,(H2,8,9,10)
InChIKey CRINBBOGNYCAOV-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 175.177 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 174
Optical Filter Setting Open
Peak Amplitude 1537
Peak Location 28696
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU F1141-1G
SMILES NS(c1cc(ccc1)F)(=O)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4