4,4'-Dithiodiphenol
SpectraBase Compound ID 2Im3VAyd5sZ
InChI InChI=1S/C12H10O2S2/c13-9-1-5-11(6-2-9)15-16-12-7-3-10(14)4-8-12/h1-8,13-14H
InChIKey XGKGITBBMXTKTE-UHFFFAOYSA-N
Mol Weight 250.33 g/mol
Molecular Formula C12H10O2S2
Exact Mass 250.012222 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID DlLj3MWvG4E
Name Bis(4-hydroxyphenyl) disulfide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B3827
Lot Number XJGOH-PK
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2003
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 15015-57-3
Calibration Lamp Spectrum Correction.0
Color Properties Pale yellow
Container ID C-009509
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C12H10O2S2
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C12H10O2S2/c13-9-1-5-11(6-2-9)15-16-12-7-3-10(14)4-8-12/h1-8,13-14H
InChIKey XGKGITBBMXTKTE-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 250.330 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 248
Optical Filter Setting Open
Peak Amplitude 1978
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B3827-1G
SMILES Oc1ccc(SSc2ccc(cc2)O)cc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 4,4'-Dihydroxydiphenyl disulfide; 4,4'-Dithiodiphenol
Technique FT-Raman
Zero Filling Factor 4