For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Magnesium(II) bis(trifluoromethanesulfonyl)imide
SpectraBase Compound ID 6hke36f4Foh
InChI InChI=1S/2C2F6NO4S2.Mg/c2*3-1(4,5)14(10,11)9-15(12,13)2(6,7)8;/q2*-1;+2
InChIKey DMFBPGIDUUNBRU-UHFFFAOYSA-N
Mol Weight 584.576 g/mol
Molecular Formula C4F12MgN2O8S4
Exact Mass 583.819629 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID DkzygMvL2Ii
Name Magnesium(II) bis(trifluoromethanesulfonyl)imide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2861
Lot Number IUNUM-AG
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270189
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1870
Backward Peak Location 7339
Beam Splitter Setting KBr
CAS Registry Number 133395-16-1
Color Properties White
Container ID C-009721
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C4F12MgN2O8S4
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/2C2F6NO4S2.Mg/c2*3-1(4,5)14(10,11)9-15(12,13)2(6,7)8;/q2*-1;+2
InChIKey DMFBPGIDUUNBRU-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1891
Peak Amplitude 2nd Channel 1
Peak Location 7396
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 10 %
Resolution 4
SKU M2861-1G
SMILES FC(F)(F)S([N-]S(=O)(=O)C(F)(F)F)(=O)=O.FC(F)(F)S([N-]S(=O)(=O)C(F)(F)F)(=O)=O.[Mg+2]
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.296 s
Scanner Temperature 26.2 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms Bis(trifluoromethanesulfonyl)imide magnesium(II) salt
Technique ATR-Neat
Zero Filling Factor 4