For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4-Chloro-m-xylene
SpectraBase Compound ID 3iRG5rayRCZ
InChI InChI=1S/C8H9Cl/c1-6-3-4-8(9)7(2)5-6/h3-5H,1-2H3
InChIKey UIEVCEQLNUHDIF-UHFFFAOYSA-N
Mol Weight 140.61 g/mol
Molecular Formula C8H9Cl
Exact Mass 140.039278 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID DfJARoIoYqR
Name 4-Chloro-m-xylene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C2165
Lot Number 3LF5N-CF
Acquisition Mode double sided, forward-backward
Actual Signal Gain 1
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.222562
Analog Signal 2 0
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Backward Peak Amplitude 3117
Backward Peak Location 28697
Beam Splitter Setting Quartz
CAS Registry Number 95-66-9
Calibration Lamp Spectrum Correction.0
Container ID C-010363
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H9Cl
Frequency of First Point 3597.77 cm⁻¹
Frequency of Last Point -0.855506 cm⁻¹
High Folding Limit 31596.9
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H9Cl/c1-6-3-4-8(9)7(2)5-6/h3-5H,1-2H3
InChIKey UIEVCEQLNUHDIF-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7465
Number of Sample Scans 216
Optical Filter Setting Open
Peak Amplitude 3089
Peak Amplitude 2nd Channel 1
Peak Location 28687
Peak Location 2nd Channel 1
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity >98.0%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Relative Humidity Interferometer 30 %
Resolution 2
SKU C2165-5G
SMILES c1c(c(ccc1C)Cl)C
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 794.596 s
Scanner Temperature 26 °C
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 1-Chloro-2,4-dimethylbenzene
Technique FT-Raman
Temperature of Calibration Lamp 2300
Zero Filling Factor 4