SpectraBase Spectrum ID |
DLTCHEhXsDS |
Name |
L-Homophenylalanine ethyl ester hydrochloride |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
H1532 |
Lot Number |
DQYNA-TH |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270233 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1874 |
Backward Peak Location |
7372 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
90891-21-7 |
Color Properties |
White |
Container ID |
C-009665 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C12H18ClNO2 |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C12H17NO2.ClH/c1-2-15-12(14)11(13)9-8-10-6-4-3-5-7-10;/h3-7,11H,2,8-9,13H2,1H3;1H/t11-;/m0./s1 |
InChIKey |
PTFKZMFFSIYCOV-MERQFXBCSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
243.734 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1875 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7364 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
97% |
Relative Humidity Interferometer |
20 % |
Resolution |
4 |
SKU |
H1532-1G |
SMILES |
Cl.N[C@@](CCc1ccccc1)(C(OCC)=O)[H] |
Sample Comments |
Sample ground at metal edge of ATR |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.311 s |
Scanner Temperature |
26.7 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
(S)-2-Amino-4-phenylbutyric acid ethyl ester hydrochloride; Ethyl (S)-2-amino-4-phenylbutyrate hydrochloride |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |