For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Acetamido-4-picoline
SpectraBase Compound ID HWGeNt7JU3p
InChI InChI=1S/C8H10N2O/c1-6-3-4-9-8(5-6)10-7(2)11/h3-5H,1-2H3,(H,9,10,11)
InChIKey QGZHGSGLCZEGHA-UHFFFAOYSA-N
Mol Weight 150.18 g/mol
Molecular Formula C8H10N2O
Exact Mass 150.079313 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID DI0nNLjhGc
Name N-(4-Methyl-2-pyridyl)acetamide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2787
Lot Number U4XRB-LN
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1497
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 5327-32-2
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009693
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H10N2O
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H10N2O/c1-6-3-4-9-8(5-6)10-7(2)11/h3-5H,1-2H3,(H,9,10,11)
InChIKey QGZHGSGLCZEGHA-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 88
Optical Filter Setting Open
Peak Amplitude 1471
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU M2787-1G
SMILES N(c1cc(ccn1)C)C(C)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 2-Acetamido-4-picoline
Technique FT-Raman
Zero Filling Factor 4