For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2',3,4,5-Tetrafluoro-4'-(trans-4-propylcyclohexyl)biphenyl
SpectraBase Compound ID 6obYwHdElV2
InChI InChI=1S/C21H22F4/c1-2-3-13-4-6-14(7-5-13)15-8-9-17(18(22)10-15)16-11-19(23)21(25)20(24)12-16/h8-14H,2-7H2,1H3/t13-,14-
InChIKey AYFPNRLYKGMWJN-HDJSIYSDSA-N
Mol Weight 350.4 g/mol
Molecular Formula C21H22F4
Exact Mass 350.165763 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID CNSrs88gWOh
Name 2',3,4,5-Tetrafluoro-4'-(trans-4-propylcyclohexyl)biphenyl
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number T3317
Lot Number XFSRG-OQ
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270497
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -9419
Backward Peak Location 14450
Beam Splitter Setting KBr
CAS Registry Number 173837-35-9
Color Properties White
Container ID C-009559
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C21H22F4
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C21H22F4/c1-2-3-13-4-6-14(7-5-13)15-8-9-17(18(22)10-15)16-11-19(23)21(25)20(24)12-16/h8-14H,2-7H2,1H3/t13-,14-
InChIKey AYFPNRLYKGMWJN-HDJSIYSDSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -9753
Peak Amplitude 2nd Channel 1
Peak Location 14506
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 2
SKU T3317-1G
SMILES C1C[C@@](CC[C@]1(c1ccc(c(c1)F)-c1cc(c(c(c1)F)F)F)[H])(CCC)[H]
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.042 s
Scanner Temperature 28.6 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Film
Window KBr Window
Zero Filling Factor 8