2-Methoxy-4-methyl-5-nitropyridine
SpectraBase Compound ID JyZZadNPL2w
InChI InChI=1S/C7H8N2O3/c1-5-3-7(12-2)8-4-6(5)9(10)11/h3-4H,1-2H3
InChIKey DJNQRLCFAHKFLZ-UHFFFAOYSA-N
Mol Weight 168.15 g/mol
Molecular Formula C7H8N2O3
Exact Mass 168.053492 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID CAzaGXlmXJR
Name 2-Methoxy-4-methyl-5-nitropyridine
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H61258
Lot Number 81202721
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270574
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1821
Backward Peak Location 7339
Beam Splitter Setting KBr
CAS Registry Number 6635-90-1
Container ID C-009921
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C7H8N2O3
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C7H8N2O3/c1-5-3-7(12-2)8-4-6(5)9(10)11/h3-4H,1-2H3
InChIKey DJNQRLCFAHKFLZ-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1839
Peak Amplitude 2nd Channel 1
Peak Location 7396
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 95%
Relative Humidity Interferometer 10 %
Resolution 4
SKU H61258-1G
SMILES O=N(=O)c1c(cc(nc1)OC)C
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.291 s
Scanner Temperature 29.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 2-Methoxy-5-nitro-4-picoline
Technique ATR-Neat
Zero Filling Factor 4