For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
1,2-Dibromo-4,5-(methylenedioxy)benzene
SpectraBase Compound ID 3ApTdFRhq31
InChI InChI=1S/C7H4Br2O2/c8-4-1-6-7(2-5(4)9)11-3-10-6/h1-2H,3H2
InChIKey WPYAICCSYGUFTK-UHFFFAOYSA-N
Mol Weight 279.91 g/mol
Molecular Formula C7H4Br2O2
Exact Mass 277.857805 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID C2426GjjsGz
Name 5,6-Dibromo-1,3-benzodioxole
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number D4737
Lot Number OGU6M-RJ
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270448
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1866
Backward Peak Location 7372
Beam Splitter Setting KBr
CAS Registry Number 5279-32-3
Color Properties White-reddish yellow
Container ID C-009569
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C7H4Br2O2
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C7H4Br2O2/c8-4-1-6-7(2-5(4)9)11-3-10-6/h1-2H,3H2
InChIKey WPYAICCSYGUFTK-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1896
Peak Amplitude 2nd Channel 1
Peak Location 7364
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 4
SKU D4737-1G
SMILES c12cc(c(cc1OCO2)Br)Br
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.307 s
Scanner Temperature 28.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 1,2-Dibromo-4,5-(methylenedioxy)benzene
Technique ATR-Neat
Zero Filling Factor 4