4-Bromo-2-(2-nitro-1-propenyl)thiophene
SpectraBase Compound ID BWB68n7bEDz
InChI InChI=1S/C7H6BrNO2S/c1-5(9(10)11)2-7-3-6(8)4-12-7/h2-4H,1H3/b5-2-
InChIKey DEFWRSIMNNRSKK-DJWKRKHSSA-N
Mol Weight 248.09 g/mol
Molecular Formula C7H6BrNO2S
Exact Mass 246.930263 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID C20XxRs1bJn
Name 4-Bromo-2-(2-nitro-1-propenyl)thiophene
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number B25060
Lot Number J8721A
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 8121
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 175205-19-3
Calibration Lamp Spectrum Correction.0
Color Properties Yellow to brown
Container ID C-009925
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C7H6BrNO2S
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C7H6BrNO2S/c1-5(9(10)11)2-7-3-6(8)4-12-7/h2-4H,1H3/b5-2-
InChIKey DEFWRSIMNNRSKK-DJWKRKHSSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 248.094 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 232
Optical Filter Setting Open
Peak Amplitude -7859
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B25060-1G
SMILES N(=O)(=O)\C(=C/c1scc(c1)Br)C
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4