For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-(4-Morpholinyl)pyridine
SpectraBase Compound ID 4EWxduKUZEl
InChI InChI=1S/C9H12N2O/c1-2-4-10-9(3-1)11-5-7-12-8-6-11/h1-4H,5-8H2
InChIKey XHPVOSNOIWGRQQ-UHFFFAOYSA-N
Mol Weight 164.21 g/mol
Molecular Formula C9H12N2O
Exact Mass 164.094963 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID C1nthURSufk
Name 2-(4-Morpholinyl)pyridine
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H55989
Lot Number 5006F19P
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270472
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 16
Background Scans or Time Scans
Backward Peak Amplitude -10963
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 24255-25-2
Container ID C-010002
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C9H12N2O
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C9H12N2O/c1-2-4-10-9(3-1)11-5-7-12-8-6-11/h1-4H,5-8H2
InChIKey XHPVOSNOIWGRQQ-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 164.208 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 16
Optical Filter Setting Open
Peak Amplitude -11025
Peak Amplitude 2nd Channel 1
Peak Location 14476
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity 96%
Relative Humidity Interferometer 10 %
Resolution 2
SKU H55989-1G
SMILES C1COCCN1c1ncccc1
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 24.988 s
Scanner Temperature 29.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 2-Morpholinopyridine
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8