SpectraBase Spectrum ID |
Brnn1wXzRZa |
Name |
5-Norbornen-2-ol |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H56994 |
Lot Number |
M09D062 |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
8 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270496 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1785 |
Backward Peak Location |
7340 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
13080-90-5 |
Comments |
mixture of endo and exo |
Container ID |
C-009175 |
Copyright |
Copyright © 2018-2025 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C7H10O |
Frequency of First Point |
3998.34 cm⁻¹ |
Frequency of Last Point |
339.463 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C7H10O/c8-7-4-5-1-2-6(7)3-5/h1-2,5-8H,3-4H2/t5-,6+,7?/m1/s1 |
InChIKey |
MKOSBHNWXFSHSW-JEAXJGTLSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
110.156 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1873 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7396 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Solid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
99% |
Relative Humidity Interferometer |
0 % |
Resolution |
4 |
SKU |
H56994-1G |
SMILES |
OC1C[C@@]2(\C=C/[C@]1(C2)[H])[H] |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Sample Storage Requirements |
2-8°C |
Scan Time |
27.296 s |
Scanner Temperature |
28.7 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
Bicyclo[2.2.1]hept-5-en-2-ol |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |