For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Ethyl 3-pyridyloxyacetate
SpectraBase Compound ID AW3biVG4grt
InChI InChI=1S/C9H11NO3/c1-2-12-9(11)7-13-8-4-3-5-10-6-8/h3-6H,2,7H2,1H3
InChIKey XNRUOZBZALSKNK-UHFFFAOYSA-N
Mol Weight 181.19 g/mol
Molecular Formula C9H11NO3
Exact Mass 181.073893 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID BMmhQwbLfbM
Name Ethyl 3-pyridyloxyacetate
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H33981
Lot Number 10170181
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2592
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 18342-98-8
Calibration Lamp Spectrum Correction.0
Color Properties Yellow
Container ID C-009987
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C9H11NO3
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29546 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C9H11NO3/c1-2-12-9(11)7-13-8-4-3-5-10-6-8/h3-6H,2,7H2,1H3
InChIKey XNRUOZBZALSKNK-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 181.191 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 240
Optical Filter Setting Open
Peak Amplitude 2531
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H33981-1G
SMILES c1c(cncc1)OCC(OCC)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 3-Pyridyloxyacetic acid ethyl ester
Technique FT-Raman
Zero Filling Factor 4