3,5-Dibromophenol
SpectraBase Compound ID J41eyZNaKLM
InChI InChI=1S/C6H4Br2O/c7-4-1-5(8)3-6(9)2-4/h1-3,9H
InChIKey PZFMWYNHJFZBPO-UHFFFAOYSA-N
Mol Weight 251.9 g/mol
Molecular Formula C6H4Br2O
Exact Mass 249.862891 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID AxOvVgmtY4D
Name 3,5-Dibromophenol
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number D3820
Lot Number EH37L-EK
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1559
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 626-41-5
Calibration Lamp Spectrum Correction.0
Color Properties White-pale yellow red
Container ID C-009476
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C6H4Br2O
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C6H4Br2O/c7-4-1-5(8)3-6(9)2-4/h1-3,9H
InChIKey PZFMWYNHJFZBPO-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 251.905 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 6
Optical Filter Setting Open
Peak Amplitude 1544
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU D3820-1G
SMILES Oc1cc(cc(c1)Br)Br
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4