Ethyl 1-bromocyclobutanecarboxylate
SpectraBase Compound ID FoKgj4e7gja
InChI InChI=1S/C7H11BrO2/c1-2-10-6(9)7(8)4-3-5-7/h2-5H2,1H3
InChIKey UTVNSHXHFRIXMM-UHFFFAOYSA-N
Mol Weight 207.07 g/mol
Molecular Formula C7H11BrO2
Exact Mass 205.994243 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID AupagcCjX8V
Name Ethyl 1-bromocyclobutanecarboxylate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number E1245
Lot Number 3UCVG-DH
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270485
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 16
Background Scans or Time Scans
Backward Peak Amplitude -11699
Backward Peak Location 14482
Beam Splitter Setting KBr
CAS Registry Number 35120-18-4
Color Properties Colorless
Container ID C-009542
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C7H11BrO2
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C7H11BrO2/c1-2-10-6(9)7(8)4-3-5-7/h2-5H2,1H3
InChIKey UTVNSHXHFRIXMM-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 207.067 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 16
Optical Filter Setting Open
Peak Amplitude -12288
Peak Amplitude 2nd Channel 1
Peak Location 14474
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Liquid
Preamplifier Gain Background 0
Purity 96%
Relative Humidity Interferometer 10 %
Resolution 2
SKU E1245-1G
SMILES C1CC(C1)(Br)C(OCC)=O
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 24.999 s
Scanner Temperature 28.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8