2,6-Dichloro-4-(trifluoromethyl)aniline
SpectraBase Compound ID BifLRBjAeXS
InChI InChI=1S/C7H4Cl2F3N/c8-4-1-3(7(10,11)12)2-5(9)6(4)13/h1-2H,13H2
InChIKey ITNMAZSPBLRJLU-UHFFFAOYSA-N
Mol Weight 230.02 g/mol
Molecular Formula C7H4Cl2F3N
Exact Mass 228.967289 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID Apyaskk9GM9
Name 2,6-Dichloro-4-(trifluoromethyl)aniline
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number B20728
Lot Number 10182789
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.27037
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -11675
Backward Peak Location 14449
Beam Splitter Setting KBr
CAS Registry Number 24279-39-8
Color Properties Light yellow
Container ID C-008361
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C7H4Cl2F3N
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C7H4Cl2F3N/c8-4-1-3(7(10,11)12)2-5(9)6(4)13/h1-2H,13H2
InChIKey ITNMAZSPBLRJLU-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 230.017 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -10891
Peak Amplitude 2nd Channel 1
Peak Location 14507
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 20 %
Resolution 2
SKU B20728-1G
SMILES C(F)(F)(F)c1cc(c(c(c1)Cl)N)Cl
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.044 s
Scanner Temperature 28.1 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 4-Amino-3,5-dichlorobenzotrifluoride
Technique Melt (Liquid)
Window KBr Window
Zero Filling Factor 8