For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Triethoxy(pentafluorophenyl)silane
SpectraBase Compound ID EB2sHCSJxfY
InChI InChI=1S/C12H15F5O3Si/c1-4-18-21(19-5-2,20-6-3)12-10(16)8(14)7(13)9(15)11(12)17/h4-6H2,1-3H3
InChIKey QALDFNLNVLQDSP-UHFFFAOYSA-N
Mol Weight 330.33 g/mol
Molecular Formula C12H15F5O3Si
Exact Mass 330.071062 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID AmTBmbGcYBl
Name Triethoxy(pentafluorophenyl)silane
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number T3134
Lot Number YDVWO-LB
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270609
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1957
Backward Peak Location 7372
Beam Splitter Setting KBr
CAS Registry Number 20083-34-5
Color Properties Pale yellow
Container ID C-009554
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C12H15F5O3Si
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C12H15F5O3Si/c1-4-18-21(19-5-2,20-6-3)12-10(16)8(14)7(13)9(15)11(12)17/h4-6H2,1-3H3
InChIKey QALDFNLNVLQDSP-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 330.326 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1949
Peak Amplitude 2nd Channel 1
Peak Location 7364
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 95%
Relative Humidity Interferometer 10 %
Resolution 4
SKU T3134-1G
SMILES c1(c(c(c(c(c1F)F)F)F)[Si](OCC)(OCC)OCC)F
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.304 s
Scanner Temperature 30.4 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4