2-Chloro-6-(trichloromethyl)pyridine
SpectraBase Compound ID DCL8E8NgUVp
InChI InChI=1S/C6H3Cl4N/c7-5-3-1-2-4(11-5)6(8,9)10/h1-3H
InChIKey DCUJJWWUNKIJPH-UHFFFAOYSA-N
Mol Weight 230.9 g/mol
Molecular Formula C6H3Cl4N
Exact Mass 228.90196 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID AhGhRjD5KDV
Name 2-Chloro-6-(trichloromethyl)pyridine
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C0961
Lot Number 78WU0-D0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1845
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 1929-82-4
Calibration Lamp Spectrum Correction.0
Color Properties White
Container ID C-009514
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C6H3Cl4N
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C6H3Cl4N/c7-5-3-1-2-4(11-5)6(8,9)10/h1-3H
InChIKey DCUJJWWUNKIJPH-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 166
Optical Filter Setting Open
Peak Amplitude 1782
Peak Location 28696
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU C0961-1G
SMILES C(Cl)(Cl)(Cl)c1cccc(n1)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4