| SpectraBase Spectrum ID |
AgdqiS7aTIF |
| Name |
Nα-(9-Fluorenylmethyloxycarbonyl)-Nε-(4-methyltrityl)-L-lysine |
| Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
| Catalog Number |
H63629 |
| Lot Number |
N02D020 |
| Accessory |
DuraSample IR #145404C7 |
| Acquisition Mode |
double sided, forward-backward |
| Actual Signal Gain |
8 |
| Actual Signal Gain 2nd Channel |
1 |
| Additional Data Treatment |
1 |
| Analog Signal 1 |
0.27041 |
| Analog Signal 2 |
0 |
| Aperture Setting |
6 mm |
| Apodization Function |
Norton-Beer, medium |
| Background Measurement Channel |
Sample Compartment |
| Background Peak Amplitude 2nd Channel |
1 |
| Background Peak Location 2nd Channel |
1 |
| Background Rotations |
32 |
| Background Scans |
32 |
| Background Scans or Time |
Scans |
| Backward Peak Amplitude |
-1779 |
| Backward Peak Location |
7370 |
| Beam Splitter Setting |
KBr |
| CAS Registry Number |
167393-62-6 |
| Container ID |
C-009905 |
| Copyright |
Copyright © 2018-2025 John Wiley & Sons, Inc. All Rights Reserved. |
| Data Point Format |
1 |
| Delay Before Measurement |
1 s |
| Detector Setting |
RT-DLaTGS [Internal] |
| End Frequency Limit for File |
340 |
| External Synchronization |
Off |
| Focal Length |
100 |
| Formula |
C41H40N2O4 |
| Frequency of First Point |
3998.29 cm⁻¹ |
| Frequency of Last Point |
339.46 cm⁻¹ |
| High Folding Limit |
15800.3 |
| High Frequency Limit |
8000 cm⁻¹ |
| High Pass Filter |
0 |
| InChI |
InChI=1S/C41H40N2O4/c1-29-23-25-32(26-24-29)41(30-14-4-2-5-15-30,31-16-6-3-7-17-31)42-27-13-12-22-38(39(44)45)43-40(46)47-28-37-35-20-10-8-18-33(35)34-19-9-11-21-36(34)37/h2-11,14-21,23-26,37-38,42H,12-13,22,27-28H2,1H3,(H,43,46)(H,44,45)/t38-/m0/s1 |
| InChIKey |
YPTNAIDIXCOZAJ-LHEWISCISA-N |
| Instrument Name |
Bruker Tensor 27 FT-IR |
| Laser Wavenumber |
15800.3 cm⁻¹ |
| Low Folding Limit |
0 |
| Low Frequency Limit |
0 |
| Low Pass Filter |
10 |
| Measurement Channel |
Sample Compartment |
| Non Linearity Correction |
0 |
| Number of Points |
3795 |
| Number of Sample Scans |
32 |
| Optical Filter Setting |
Open |
| Peak Amplitude |
-1861 |
| Peak Amplitude 2nd Channel |
1 |
| Peak Location |
7366 |
| Peak Location 2nd Channel |
1 |
| Phase Correction Mode |
Mertz |
| Phase Resolution |
8 |
| Physical State |
Liquid |
| Preamplifier Gain |
3 |
| Preamplifier Gain Background |
0 |
| Purity |
95% |
| Relative Humidity Interferometer |
20 % |
| Resolution |
4 |
| SKU |
H63629-1G |
| SMILES |
N(C(c1ccc(cc1)C)(c1ccccc1)c1ccccc1)CCCC[C@@](C(O)=O)(NC(=O)OCC1c2ccccc2-c2ccccc12)[H] |
| Sample Rotations |
32 |
| Sample Scans or Time |
Scans |
| Sample Spacing Divisor |
1 |
| Sample Spacing Multiplicator |
1 |
| Scan Time |
27.293 s |
| Scanner Temperature |
28.3 °C |
| Scanner Velocity |
10 kHz |
| Signal Gain, Background |
automatic |
| Signal Gain, Sample |
automatic |
| Source of Spectrum |
Bio-Rad Laboratories, Inc. |
| Start Frequency Limit for File |
4000 cm⁻¹ |
| Synonyms |
Fmoc-Lys(Mtt)-OH |
| Technique |
ATR-Neat |
| Zero Filling Factor |
4 |