For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Pyrrolidine hydrobromide
SpectraBase Compound ID 1fDpkNZeDnw
InChI InChI=1S/C4H9N.BrH/c1-2-4-5-3-1;/h5H,1-4H2;1H
InChIKey VFDOIPKMSSDMCV-UHFFFAOYSA-N
Mol Weight 152.03 g/mol
Molecular Formula C4H10BrN
Exact Mass 150.999662 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID Addnr0zuFLM
Name Pyrrolidine hydrobromide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number P2484
Lot Number GUPDO-QS
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270942
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -9669
Backward Peak Location 14479
Beam Splitter Setting KBr
CAS Registry Number 55810-80-5
Color Properties White-pale reddish yellow
Container ID C-009705
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C4H10BrN
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C4H9N.BrH/c1-2-4-5-3-1;/h5H,1-4H2;1H
InChIKey VFDOIPKMSSDMCV-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 152.035 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -9500
Peak Amplitude 2nd Channel 1
Peak Location 14477
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 2
SKU P2484-1G
SMILES Br.N1CCCC1
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.028 s
Scanner Temperature 33.7 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Neat
Window KBr Window - 1 Side
Zero Filling Factor 8