For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4-(4,4,5,5-Tetramethyl-1,3,2-dioxaborolan-2-yl)benzyl alcohol
SpectraBase Compound ID fxRC4alDPC
InChI InChI=1S/C13H19BO3/c1-12(2)13(3,4)17-14(16-12)11-7-5-10(9-15)6-8-11/h5-8,15H,9H2,1-4H3
InChIKey GZZBZWITJNATOD-UHFFFAOYSA-N
Mol Weight 234.1 g/mol
Molecular Formula C13H19BO3
Exact Mass 234.142725 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID AZdqPU57vB5
Name 4-(4,4,5,5-Tetramethyl-1,3,2-dioxaborolan-2-yl)benzyl alcohol
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number T3496
Lot Number VTACC-TI
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 1384
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 302348-51-2
Calibration Lamp Spectrum Correction.0
Container ID C-009452
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C13H19BO3
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C13H19BO3/c1-12(2)13(3,4)17-14(16-12)11-7-5-10(9-15)6-8-11/h5-8,15H,9H2,1-4H3
InChIKey GZZBZWITJNATOD-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 234.102 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 180
Optical Filter Setting Open
Peak Amplitude 1385
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU T3496-1G
SMILES OCc1ccc(cc1)B1OC(C(O1)(C)C)(C)C
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 4-(Hydroxymethyl)phenylboronic acid pinacol ester
Technique FT-Raman
Zero Filling Factor 4