2'-Amino-4',5'-dimethoxyacetophenone
SpectraBase Compound ID AAXDmhUvUvz
InChI InChI=1S/C10H13NO3/c1-6(12)7-4-9(13-2)10(14-3)5-8(7)11/h4-5H,11H2,1-3H3
InChIKey KGKWXEGYKGTMAK-UHFFFAOYSA-N
Mol Weight 195.22 g/mol
Molecular Formula C10H13NO3
Exact Mass 195.089543 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID APNCAyNuyJX
Name 2'-Amino-4',5'-dimethoxyacetophenone
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2842
Lot Number INK8A-MS
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 5106
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 4101-30-8
Calibration Lamp Spectrum Correction.0
Color Properties Yellow
Container ID C-009459
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C10H13NO3
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C10H13NO3/c1-6(12)7-4-9(13-2)10(14-3)5-8(7)11/h4-5H,11H2,1-3H3
InChIKey KGKWXEGYKGTMAK-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 256
Optical Filter Setting Open
Peak Amplitude 5016
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU A2842-1G
SMILES Nc1cc(c(cc1C(C)=O)OC)OC
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4