For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-Benzyloxy-benzylalcohol
SpectraBase Compound ID 3DsoDBG0LPm
InChI InChI=1S/C14H14O2/c15-10-13-7-4-8-14(9-13)16-11-12-5-2-1-3-6-12/h1-9,15H,10-11H2
InChIKey AFKLSWIRJUJWKY-UHFFFAOYSA-N
Mol Weight 214.26 g/mol
Molecular Formula C14H14O2
Exact Mass 214.09938 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID ALymFHkoKxA
Name 3-Benzyloxybenzyl alcohol
Source of Sample Acros Organics
Catalog Number 181940010
Lot Number A0234908
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270318
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -10862
Backward Peak Location 14449
Beam Splitter Setting KBr
CAS Registry Number 1700-30-7
Color Properties Light yellow to light beige
Container ID C-008500
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C14H14O2
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C14H14O2/c15-10-13-7-4-8-14(9-13)16-11-12-5-2-1-3-6-12/h1-9,15H,10-11H2
InChIKey AFKLSWIRJUJWKY-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 214.264 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -10797
Peak Amplitude 2nd Channel 1
Peak Location 14506
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 97%
Relative Humidity Interferometer 20 %
Resolution 2
SKU 181940010-1GR
SMILES OCc1cc(ccc1)OCc1ccccc1
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.045 s
Scanner Temperature 27.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms (3-Phenylmethoxyphenyl)methanol
Technique Film
Window KBr Window
Zero Filling Factor 8