For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
1-Bromo-3-fluoro-2-nitrobenzene
SpectraBase Compound ID KPmysthTT17
InChI InChI=1S/C6H3BrFNO2/c7-4-2-1-3-5(8)6(4)9(10)11/h1-3H
InChIKey VFPAOFBPEYCAAZ-UHFFFAOYSA-N
Mol Weight 220.0 g/mol
Molecular Formula C6H3BrFNO2
Exact Mass 218.93312 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID ADPxDJ2c55V
Name 1-Bromo-3-fluoro-2-nitrobenzene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B4842
Lot Number A2UHO-HI
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270592
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -10954
Backward Peak Location 14450
Beam Splitter Setting KBr
CAS Registry Number 886762-70-5
Color Properties Pale yellow
Container ID C-009715
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C6H3BrFNO2
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C6H3BrFNO2/c7-4-2-1-3-5(8)6(4)9(10)11/h1-3H
InChIKey VFPAOFBPEYCAAZ-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 219.997 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -11237
Peak Amplitude 2nd Channel 1
Peak Location 14506
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 2
SKU B4842-1G
SMILES N(=O)(=O)c1c(cccc1Br)F
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.04 s
Scanner Temperature 28.6 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Melt (Liquid)
Window KBr Window
Zero Filling Factor 8