2-Bromo-6-chlorotoluene
SpectraBase Compound ID 7nNG3dsdR76
InChI InChI=1S/C7H6BrCl/c1-5-6(8)3-2-4-7(5)9/h2-4H,1H3
InChIKey DMARBQGIQKLIPM-UHFFFAOYSA-N
Mol Weight 205.48 g/mol
Molecular Formula C7H6BrCl
Exact Mass 203.934141 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID A3xFPy8Or48
Name 2-Bromo-6-chlorotoluene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B2032
Lot Number HR6AK-ME
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270546
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1481
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 62356-27-8
Color Properties Colorless-pale yellow
Container ID C-010301
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C7H6BrCl
Frequency of First Point 3998.31 cm⁻¹
Frequency of Last Point 339.461 cm⁻¹
High Folding Limit 15800.4
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C7H6BrCl/c1-5-6(8)3-2-4-7(5)9/h2-4H,1H3
InChIKey DMARBQGIQKLIPM-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1530
Peak Amplitude 2nd Channel 1
Peak Location 7365
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 0 %
Resolution 4
SKU B2032-5G
SMILES c1c(c(c(cc1)Br)C)Cl
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.3 s
Scanner Temperature 29.2 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4