SpectraBase Spectrum ID |
A1Cujwi8YrF |
Name |
N-((((9H-Fluoren-9-yl)methoxy)carbonyl)amino)-D-threoninol |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H66956 |
Lot Number |
81400994 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270496 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-8395 |
Backward Peak Location |
14450 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
252049-02-8 |
Container ID |
C-009204 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C19H21NO4 |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C19H21NO4/c1-12(22)18(10-21)20-19(23)24-11-17-15-8-4-2-6-13(15)14-7-3-5-9-16(14)17/h2-9,12,17-18,21-22H,10-11H2,1H3,(H,20,23)/t12-,18-/m0/s1 |
InChIKey |
YOKDHMTZJSRRIQ-SGTLLEGYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-8642 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14506 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
20 % |
Resolution |
2 |
SKU |
H66956-1G |
SMILES |
OC[C@@]([C@](C)(O)[H])(NC(OCC1c2ccccc2-c2ccccc12)=O)[H] |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.04 s |
Scanner Temperature |
29.6 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
9H-Fluoren-9-ylmethyl N-[(2S,3S)-1,3-dihydroxybutan-2-yl]carbamate |
Technique |
KBr0 |
Zero Filling Factor |
8 |