For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
N-((((9H-Fluoren-9-yl)methoxy)carbonyl)amino)-D-threoninol
SpectraBase Compound ID En29xSYUT9k
InChI InChI=1S/C19H21NO4/c1-12(22)18(10-21)20-19(23)24-11-17-15-8-4-2-6-13(15)14-7-3-5-9-16(14)17/h2-9,12,17-18,21-22H,10-11H2,1H3,(H,20,23)/t12-,18-/m0/s1
InChIKey YOKDHMTZJSRRIQ-SGTLLEGYSA-N
Mol Weight 327.38 g/mol
Molecular Formula C19H21NO4
Exact Mass 327.147058 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID A1Cujwi8YrF
Name N-((((9H-Fluoren-9-yl)methoxy)carbonyl)amino)-D-threoninol
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H66956
Lot Number 81400994
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270496
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -8395
Backward Peak Location 14450
Beam Splitter Setting KBr
CAS Registry Number 252049-02-8
Container ID C-009204
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C19H21NO4
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C19H21NO4/c1-12(22)18(10-21)20-19(23)24-11-17-15-8-4-2-6-13(15)14-7-3-5-9-16(14)17/h2-9,12,17-18,21-22H,10-11H2,1H3,(H,20,23)/t12-,18-/m0/s1
InChIKey YOKDHMTZJSRRIQ-SGTLLEGYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -8642
Peak Amplitude 2nd Channel 1
Peak Location 14506
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 20 %
Resolution 2
SKU H66956-1G
SMILES OC[C@@]([C@](C)(O)[H])(NC(OCC1c2ccccc2-c2ccccc12)=O)[H]
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.04 s
Scanner Temperature 29.6 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 9H-Fluoren-9-ylmethyl N-[(2S,3S)-1,3-dihydroxybutan-2-yl]carbamate
Technique KBr0
Zero Filling Factor 8