SpectraBase Spectrum ID |
9kQxu4BWLbF |
Name |
2,4-Dimethoxyphenyl isothiocyanate |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
L12584 |
Lot Number |
10168634 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270479 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-7988 |
Backward Peak Location |
14449 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
33904-03-9 |
Color Properties |
Yellow |
Container ID |
C-009106 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C9H9NO2S |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C9H9NO2S/c1-11-7-3-4-8(10-6-13)9(5-7)12-2/h3-5H,1-2H3 |
InChIKey |
CNXSCEPTSXPBTP-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
195.236 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-7778 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14507 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
97% |
Relative Humidity Interferometer |
20 % |
Resolution |
2 |
SKU |
L12584-1G |
SMILES |
c1c(c(cc(c1)OC)OC)N=C=S |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.04 s |
Scanner Temperature |
28.8 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Solvent |
Dichloromethane |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
1-Isothiocyanato-2,4-dimethoxybenzene |
Technique |
Film |
Window |
KBr Window |
Zero Filling Factor |
8 |