SpectraBase Spectrum ID |
9jAIHTyv0GT |
Name |
Bis(cis-3,3,5-trimethylcyclohexyl) phthalate |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
P0946 |
Lot Number |
FIGNK-EP |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
1 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.222559 |
Analog Signal 2 |
0 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Backward Peak Amplitude |
2586 |
Backward Peak Location |
28701 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
245652-81-7 |
Calibration Lamp Spectrum |
Correction.0 |
Container ID |
C-010458 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C26H38O4 |
Frequency of First Point |
3597.77 cm⁻¹ |
Frequency of Last Point |
-0.855506 cm⁻¹ |
High Folding Limit |
31596.9 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C26H38O4/c1-17-11-19(15-25(3,4)13-17)29-23(27)21-9-7-8-10-22(21)24(28)30-20-12-18(2)14-26(5,6)16-20/h7-10,17-20H,11-16H2,1-6H3/t17-,18+,19+,20- |
InChIKey |
ATHBXDPWCKSOLE-JVSBHGNQSA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Non Linearity Correction |
0 |
Number of Points |
7465 |
Number of Sample Scans |
174 |
Optical Filter Setting |
Open |
Peak Amplitude |
2533 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
28683 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Solid |
Preamplifier Gain |
0 |
Purity |
>98.0% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Relative Humidity Interferometer |
30 % |
Resolution |
2 |
SKU |
P0946-5G |
SMILES |
c1c(c(ccc1)C(O[C@@]1(CC(C[C@@](C1)(C)[H])(C)C)[H])=O)C(O[C@@]1(C[C@@](CC(C1)(C)C)(C)[H])[H])=O |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
794.638 s |
Scanner Temperature |
25.2 °C |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
Phthalic acid bis(cis-3,3,5-trimethylcyclohexyl) ester |
Technique |
FT-Raman |
Temperature of Calibration Lamp |
2300 |
Zero Filling Factor |
4 |