SpectraBase Spectrum ID |
9PUuM8UAGPU |
Name |
Nα-(9-Fluorenylmethyloxycarbonyl)-Nε-(4-methyltrityl)-L-lysine |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
H63629 |
Lot Number |
N02D020 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Additional Data Treatment |
1 |
Aperture Setting |
2.5 mm |
Apodization Function |
Norton-Beer, medium |
Backward Peak Amplitude |
8589 |
Backward Peak Location |
28687 |
Beam Splitter Setting |
Quartz |
CAS Registry Number |
167393-62-6 |
Calibration Lamp Spectrum |
Correction.0 |
Container ID |
C-009905 |
Copyright |
Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
15 s |
Detector Setting |
LN-Ge Diode [Internal Pos.2] |
End Frequency Limit for File |
9394.3 |
External Analog Signals |
Off |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C41H40N2O4 |
Frequency of First Point |
3597.79 cm⁻¹ |
Frequency of Last Point |
-1.31092 cm⁻¹ |
High Folding Limit |
31596.8 |
High Frequency Limit |
30000 cm⁻¹ |
High Pass Filter |
1 |
InChI |
InChI=1S/C41H40N2O4/c1-29-23-25-32(26-24-29)41(30-14-4-2-5-15-30,31-16-6-3-7-17-31)42-27-13-12-22-38(39(44)45)43-40(46)47-28-37-35-20-10-8-18-33(35)34-19-9-11-21-36(34)37/h2-11,14-21,23-26,37-38,42H,12-13,22,27-28H2,1H3,(H,43,46)(H,44,45)/t38-/m0/s1 |
InChIKey |
YPTNAIDIXCOZAJ-LHEWISCISA-N |
Instrument Name |
Bruker MultiRAM Stand Alone FT-Raman Spectrometer |
Laser Wavenumber |
15798.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
5 |
Measurement Channel |
Raman Compartment |
Non Linearity Correction |
0 |
Number of Points |
7466 |
Number of Sample Scans |
252 |
Optical Filter Setting |
Open |
Peak Amplitude |
-8208 |
Peak Location |
28693 |
Phase Correction Mode |
power spectrum |
Phase Resolution |
1 |
Physical State |
Liquid |
Preamplifier Gain |
0 |
Purity |
95% |
Raman Background Corrected |
Yes |
Raman Corrections |
Referenced to internal light source; Scattering corrected |
Raman Laser Source |
Nd:YAG |
Raman Scattering Corrected |
Yes |
Resolution |
2 |
SKU |
H63629-1G |
SMILES |
N(C(c1ccc(cc1)C)(c1ccccc1)c1ccccc1)CCCC[C@@](C(O)=O)(NC(=O)OCC1c2ccccc2-c2ccccc12)[H] |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
2 |
Scan Time |
0 s |
Scanner Velocity |
5 kHz |
Signal Gain, Sample |
2 |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
5794.76 cm⁻¹ |
Synonyms |
Fmoc-Lys(Mtt)-OH |
Technique |
FT-Raman |
Zero Filling Factor |
4 |