For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Amino-N-(2-chloro-6-methylphenyl)thiazole-5-carboxamide
SpectraBase Compound ID CsiezVV3G3S
InChI InChI=1S/C11H10ClN3OS/c1-6-3-2-4-7(12)9(6)15-10(16)8-5-14-11(13)17-8/h2-5H,1H3,(H2,13,14)(H,15,16)
InChIKey VVOXTERFTAJMAA-UHFFFAOYSA-N
Mol Weight 267.73 g/mol
Molecular Formula C11H10ClN3OS
Exact Mass 267.023311 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 99tn04cLIG3
Name 2-Amino-N-(2-chloro-6-methylphenyl)thiazole-5-carboxamide
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number A2773
Lot Number 4Z40K-KL
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270319
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1785
Backward Peak Location 7372
Beam Splitter Setting KBr
CAS Registry Number 302964-24-5
Color Properties White-pale yellow
Container ID C-009444
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C11H10ClN3OS
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C11H10ClN3OS/c1-6-3-2-4-7(12)9(6)15-10(16)8-5-14-11(13)17-8/h2-5H,1H3,(H2,13,14)(H,15,16)
InChIKey VVOXTERFTAJMAA-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 267.734 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1795
Peak Amplitude 2nd Channel 1
Peak Location 7364
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 4
SKU A2773-1G
SMILES N(c1c(cccc1C)Cl)C(c1cnc(s1)N)=O
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.311 s
Scanner Temperature 27 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 2-Amino-N-thiazole-5-carboxamide
Technique ATR-Neat
Zero Filling Factor 4