4-Bromo-1-chloro-2-fluorobenzene
SpectraBase Compound ID CrNYp1wET2N
InChI InChI=1S/C6H3BrClF/c7-4-1-2-5(8)6(9)3-4/h1-3H
InChIKey AGYWDGVTLKNTBS-UHFFFAOYSA-N
Mol Weight 209.45 g/mol
Molecular Formula C6H3BrClF
Exact Mass 207.909069 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 8sXpNUWopGW
Name 4-Bromo-1-chloro-2-fluorobenzene
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number B1861
Lot Number 7CMKJ-JJ
Acquisition Mode double sided, forward-backward
Actual Signal Gain 1
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.222568
Analog Signal 2 0
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Backward Peak Amplitude 1689
Backward Peak Location 28681
Beam Splitter Setting Quartz
CAS Registry Number 60811-18-9
Calibration Lamp Spectrum Correction.0
Color Properties Colorless-pale yellow
Container ID C-010275
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C6H3BrClF
Frequency of First Point 3597.77 cm⁻¹
Frequency of Last Point -0.855506 cm⁻¹
High Folding Limit 31596.9
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C6H3BrClF/c7-4-1-2-5(8)6(9)3-4/h1-3H
InChIKey AGYWDGVTLKNTBS-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 209.445 g/mol
Non Linearity Correction 0
Number of Points 7465
Number of Sample Scans 88
Optical Filter Setting Open
Peak Amplitude -1676
Peak Amplitude 2nd Channel 1
Peak Location 28699
Peak Location 2nd Channel 1
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity >98.0%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Relative Humidity Interferometer 30 %
Resolution 2
SKU B1861-5G
SMILES c1c(c(cc(c1)Br)F)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 794.685 s
Scanner Temperature 25.6 °C
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Temperature of Calibration Lamp 2300
Zero Filling Factor 4