SpectraBase Spectrum ID |
8n1tf2PMc8X |
Name |
N-tert-Butyloxycarbonyl-L-isoleucinol |
Source of Sample |
Alfa Aesar, Thermo Fisher Scientific |
Catalog Number |
L19351 |
Lot Number |
10126908 |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270502 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-11021 |
Backward Peak Location |
14479 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
106946-74-1 |
Color Properties |
Colorless |
Container ID |
C-009916 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C11H23NO3 |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C11H23NO3/c1-6-8(2)9(7-13)12-10(14)15-11(3,4)5/h8-9,13H,6-7H2,1-5H3,(H,12,14)/t8-,9+/m0/s1 |
InChIKey |
BPLDQMXXYMKQPW-DTWKUNHWSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
217.309 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-10290 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14477 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Liquid |
Preamplifier Gain Background |
0 |
Purity |
95% |
Relative Humidity Interferometer |
10 % |
Resolution |
2 |
SKU |
L19351-1G |
SMILES |
N(C(OC(C)(C)C)=O)[C@](CO)([C@](CC)(C)[H])[H] |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.044 s |
Scanner Temperature |
28.9 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
N-Boc-(2S)-Amino-(3S)-methyl-1-pentanol; N-(tert-Butoxycarbonyl)-L-isoleucinol |
Technique |
Neat |
Window |
KBr Window - 1 Side |
Zero Filling Factor |
8 |