For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-Chloro-5-fluorobenzonitrile
SpectraBase Compound ID DLR2bJL7wB6
InChI InChI=1S/C7H3ClFN/c8-6-1-5(4-10)2-7(9)3-6/h1-3H
InChIKey GIKLRWNRBOLRDV-UHFFFAOYSA-N
Mol Weight 155.56 g/mol
Molecular Formula C7H3ClFN
Exact Mass 154.993805 g/mol

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 8c1012JLPv3
Name 3-Chloro-5-fluorobenzonitrile
Source of Sample Acros Organics
Catalog Number 374770010
Lot Number A093214
Accessory TRANS *14560FA0
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 0
Analog Signal 1 0.270376
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -10137
Backward Peak Location 14450
Beam Splitter Setting KBr
CAS Registry Number 327056-73-5
Color Properties Light yellow
Container ID C-008614
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 0 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C7H3ClFN
Frequency of First Point 3999.54 cm⁻¹
Frequency of Last Point 339.945 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C7H3ClFN/c8-6-1-5(4-10)2-7(9)3-6/h1-3H
InChIKey GIKLRWNRBOLRDV-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Molecular Weight 155.559 g/mol
Non Linearity Correction 0
Number of Points 15180
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -10047
Peak Amplitude 2nd Channel 1
Peak Location 14507
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 4
Physical State Solid
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 2
SKU 374770010-1GR
SMILES c1c(cc(cc1C#N)F)Cl
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 50.044 s
Scanner Temperature 28.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Solvent Dichloromethane
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique Film
Window KBr Window
Zero Filling Factor 8