4-(3,4-Dichlorophenyl)-1-tetralone
SpectraBase Compound ID HwULOdBU3Xs
InChI InChI=1S/C16H12Cl2O/c17-14-7-5-10(9-15(14)18)11-6-8-16(19)13-4-2-1-3-12(11)13/h1-5,7,9,11H,6,8H2
InChIKey JGMBHJNMQVKDMW-UHFFFAOYSA-N
Mol Weight 291.18 g/mol
Molecular Formula C16H12Cl2O
Exact Mass 290.02652 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 8XCHQwS9QZ7
Name 4-(3,4-Dichlorophenyl)-1-tetralone
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number D4766
Lot Number KYIGO-OG
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2426
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 79560-19-3
Calibration Lamp Spectrum Correction.0
Color Properties White-pale yellow
Container ID C-009734
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C16H12Cl2O
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C16H12Cl2O/c17-14-7-5-10(9-15(14)18)11-6-8-16(19)13-4-2-1-3-12(11)13/h1-5,7,9,11H,6,8H2
InChIKey JGMBHJNMQVKDMW-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 144
Optical Filter Setting Open
Peak Amplitude 2396
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU D4766-1G
SMILES c12ccccc1C(CCC2=O)c1ccc(c(c1)Cl)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 4-(3,4-Dichlorophenyl)-3,4-dihydro-1(2H)-naphthalenone
Technique FT-Raman
Zero Filling Factor 4