SpectraBase Spectrum ID |
8O77iOb1vFt |
Name |
6,6',7,7'-Tetrahydroxy-4,4,4',4'-tetramethyl-2,2'-spirobichroman |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
T1791 |
Lot Number |
GL01-JLED |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
16 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270493 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1430 |
Backward Peak Location |
7370 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
32737-35-2 |
Color Properties |
Pale yellow - Yellow red |
Container ID |
C-010278 |
Copyright |
Copyright © 2018-2025 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C21H24O6 |
Frequency of First Point |
3998.31 cm⁻¹ |
Frequency of Last Point |
339.461 cm⁻¹ |
High Folding Limit |
15800.4 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C21H24O6/c1-19(2)9-21(26-17-7-15(24)13(22)5-11(17)19)10-20(3,4)12-6-14(23)16(25)8-18(12)27-21/h5-8,22-25H,9-10H2,1-4H3 |
InChIKey |
SZUGPQFFJXSTDD-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
372.417 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1497 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7366 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Physical State |
Liquid |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
>98.0% |
Relative Humidity Interferometer |
0 % |
Resolution |
4 |
SKU |
T1791-5G |
SMILES |
Oc1cc2C(CC3(Oc2cc1O)CC(c1cc(c(cc1O3)O)O)(C)C)(C)C |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.337 s |
Scanner Temperature |
27.8 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
4,4,4',4'-Tetramethyl-2,2'-spirobi[chroman]-6,6',7,7'-tetraol |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |