For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
N-Methoxy-N-methylcarbamoyl chloride
SpectraBase Compound ID FwYRk78p8fU
InChI InChI=1S/C3H6ClNO2/c1-5(7-2)3(4)6/h1-2H3
InChIKey SHQJHXLWZDMQEJ-UHFFFAOYSA-N
Mol Weight 123.54 g/mol
Molecular Formula C3H6ClNO2
Exact Mass 123.008706 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 89PKrMj4nXp
Name N-Methoxy-N-methylcarbamoyl chloride
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2117
Lot Number QB3BK-FO
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270395
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1938
Backward Peak Location 7370
Beam Splitter Setting KBr
CAS Registry Number 30289-28-2
Color Properties Colorless
Container ID C-009735
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C3H6ClNO2
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C3H6ClNO2/c1-5(7-2)3(4)6/h1-2H3
InChIKey SHQJHXLWZDMQEJ-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1891
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Liquid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 10 %
Resolution 4
SKU M2117-1G
SMILES CN(C(Cl)=O)OC
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.309 s
Scanner Temperature 28.2 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4