For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Pentafluorophenyl 4-nitrobenzenesulfonate
SpectraBase Compound ID LWRMucXrZuT
InChI InChI=1S/C12H4F5NO5S/c13-7-8(14)10(16)12(11(17)9(7)15)23-24(21,22)6-3-1-5(2-4-6)18(19)20/h1-4H
InChIKey DQKVZFMQPLLPMR-UHFFFAOYSA-N
Mol Weight 369.22 g/mol
Molecular Formula C12H4F5NO5S
Exact Mass 368.973034 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 7wiPMoPPYIM
Name Pentafluorophenyl 4-nitrobenzenesulfonate
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number P2231
Lot Number DPI3A-JR
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 8
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270218
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -2017
Backward Peak Location 7369
Beam Splitter Setting KBr
CAS Registry Number 244633-31-6
Color Properties White
Container ID C-009689
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C12H4F5NO5S
Frequency of First Point 3998.34 cm⁻¹
Frequency of Last Point 339.463 cm⁻¹
High Folding Limit 15800.5
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C12H4F5NO5S/c13-7-8(14)10(16)12(11(17)9(7)15)23-24(21,22)6-3-1-5(2-4-6)18(19)20/h1-4H
InChIKey DQKVZFMQPLLPMR-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.5 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 369.218 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -2040
Peak Amplitude 2nd Channel 1
Peak Location 7366
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity 98%
Relative Humidity Interferometer 0 %
Resolution 4
SKU P2231-1G
SMILES N(=O)(=O)c1ccc(cc1)S(=O)(=O)Oc1c(c(c(c(c1F)F)F)F)F
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.298 s
Scanner Temperature 25.9 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Technique ATR-Neat
Zero Filling Factor 4