4-Hydroxy-4'-nitrostilbene
SpectraBase Compound ID AnuouNNR4r6
InChI InChI=1S/C14H11NO3/c16-14-9-5-12(6-10-14)2-1-11-3-7-13(8-4-11)15(17)18/h1-10,16H/b2-1+
InChIKey OETQWIHJPIESQB-OWOJBTEDSA-N
Mol Weight 241.25 g/mol
Molecular Formula C14H11NO3
Exact Mass 241.073893 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 7vFpUyx4Ftd
Name 4-Hydroxy-4'-nitrostilbene
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number B20913
Lot Number 10150620
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 9863
Backward Peak Location 28687
Beam Splitter Setting Quartz
Calibration Lamp Spectrum Correction.0
Color Properties Brown
Container ID C-009844
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C14H11NO3
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C14H11NO3/c16-14-9-5-12(6-10-14)2-1-11-3-7-13(8-4-11)15(17)18/h1-10,16H/b2-1+
InChIKey OETQWIHJPIESQB-OWOJBTEDSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 241.246 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 254
Optical Filter Setting Open
Peak Amplitude -9533
Peak Location 28700
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 98%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU B20913-1G
SMILES N(=O)(=O)c1ccc(\C=C\c2ccc(cc2)O)cc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 4-[(E)-2-(4-Nitrophenyl)ethenyl]phenol
Technique FT-Raman
Zero Filling Factor 4