For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
4,4''-Dinitro-p-terphenyl
SpectraBase Compound ID vmTGBjIVY4
InChI InChI=1S/C18H12N2O4/c21-19(22)17-9-5-15(6-10-17)13-1-2-14(4-3-13)16-7-11-18(12-8-16)20(23)24/h1-12H
InChIKey MHOAYDHUNGLDTB-UHFFFAOYSA-N
Mol Weight 320.3 g/mol
Molecular Formula C18H12N2O4
Exact Mass 320.079707 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 7ur2Pgjkkzs
Name 4,4''-Dinitro-p-terphenyl
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number D3394
Lot Number 4XRETRE-IP
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 10423
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 3282-11-9
Calibration Lamp Spectrum Correction.0
Container ID C-009466
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C18H12N2O4
Frequency of First Point 3597.8 cm⁻¹
Frequency of Last Point -1.29183 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C18H12N2O4/c21-19(22)17-9-5-15(6-10-17)13-1-2-14(4-3-13)16-7-11-18(12-8-16)20(23)24/h1-12H
InChIKey MHOAYDHUNGLDTB-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 320.304 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 256
Optical Filter Setting Open
Peak Amplitude -9910
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU D3394-1G
SMILES N(=O)(=O)c1ccc(-c2ccc(-c3ccc(cc3)N(=O)=O)cc2)cc1
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4