7-Chloroisatin
SpectraBase Compound ID A4QoL8R16iN
InChI InChI=1S/C8H4ClNO2/c9-5-3-1-2-4-6(5)10-8(12)7(4)11/h1-3H,(H,10,11,12)
InChIKey MPLXQMMMGDYXIT-UHFFFAOYSA-N
Mol Weight 181.58 g/mol
Molecular Formula C8H4ClNO2
Exact Mass 180.993056 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 7mthN5lXWQx
Name 7-Chloroisatin
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number C2840
Lot Number DCIBK-GI
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2751
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 7477-63-6
Calibration Lamp Spectrum Correction.0
Color Properties Deep reddish yellow
Container ID C-009600
Copyright Copyright © 2017-2025 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H4ClNO2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H4ClNO2/c9-5-3-1-2-4-6(5)10-8(12)7(4)11/h1-3H,(H,10,11,12)
InChIKey MPLXQMMMGDYXIT-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 116
Optical Filter Setting Open
Peak Amplitude 2745
Peak Location 28692
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU C2840-1G
SMILES N1c2c(cccc2C(C1=O)=O)Cl
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Synonyms 7-Chloro-2,3-indolinedione
Technique FT-Raman
Zero Filling Factor 4