SpectraBase Spectrum ID |
7S4dJpqPz5E |
Name |
Ceftezole |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
C2770 |
Lot Number |
G60FJ-MG |
Accessory |
DuraSample IR #145404C7 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
16 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
1 |
Analog Signal 1 |
0.270564 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Rotations |
32 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-1372 |
Backward Peak Location |
7370 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
26973-24-0 |
Color Properties |
Pale yellow |
Container ID |
C-010328 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
1 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C13H12N8O4S3 |
Frequency of First Point |
3998.31 cm⁻¹ |
Frequency of Last Point |
339.461 cm⁻¹ |
High Folding Limit |
15800.4 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C13H12N8O4S3/c22-7(1-20-4-14-18-19-20)16-8-10(23)21-9(12(24)25)6(2-26-11(8)21)3-27-13-17-15-5-28-13/h4-5,8,11H,1-3H2,(H,16,22)(H,24,25)/t8-,11?/m1/s1 |
InChIKey |
DZMVCVMFETWNIU-RZZZFEHKSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.4 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Measurement Channel |
Sample Compartment |
Molecular Weight |
440.471 g/mol |
Non Linearity Correction |
0 |
Number of Points |
3795 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-1403 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
7365 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
8 |
Preamplifier Gain |
3 |
Preamplifier Gain Background |
0 |
Purity |
>98.0% |
Relative Humidity Interferometer |
0 % |
Resolution |
4 |
SKU |
C2770-5G |
SMILES |
N([C@]1(C2SC\C(=C\(C(O)=O)N2C1=O)CSc1nncs1)[H])C(C[n]1nnnc1)=O |
Sample Rotations |
32 |
Sample Scans or Time |
Scans |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
27.299 s |
Scanner Temperature |
29.1 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Signal Gain, Sample |
automatic |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
(6R,7R)-8-Oxo-7-[(1H-tetrazol-1-ylacetyl)amino]-3-[(1,3,4-thiadiazol-2-ylthio)methyl]-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid |
Technique |
ATR-Neat |
Zero Filling Factor |
4 |