For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
Triethoxy(pentafluorophenyl)silane
SpectraBase Compound ID EB2sHCSJxfY
InChI InChI=1S/C12H15F5O3Si/c1-4-18-21(19-5-2,20-6-3)12-10(16)8(14)7(13)9(15)11(12)17/h4-6H2,1-3H3
InChIKey QALDFNLNVLQDSP-UHFFFAOYSA-N
Mol Weight 330.33 g/mol
Molecular Formula C12H15F5O3Si
Exact Mass 330.071062 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 6bkgxk9SxRA
Name Triethoxy(pentafluorophenyl)silane
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number T3134
Lot Number YDVWO-LB
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 693
Backward Peak Location 28691
Beam Splitter Setting Quartz
CAS Registry Number 20083-34-5
Calibration Lamp Spectrum Correction.0
Color Properties Pale yellow
Container ID C-009554
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C12H15F5O3Si
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C12H15F5O3Si/c1-4-18-21(19-5-2,20-6-3)12-10(16)8(14)7(13)9(15)11(12)17/h4-6H2,1-3H3
InChIKey QALDFNLNVLQDSP-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 330.326 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 2
Optical Filter Setting Open
Peak Amplitude -684
Peak Location 28688
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Liquid
Preamplifier Gain 0
Purity 95%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU T3134-1G
SMILES c1(c(c(c(c(c1F)F)F)F)[Si](OCC)(OCC)OCC)F
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4