For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
SpectraBase Compound ID 2boElRk2oaK

Transmission Infrared (IR) Spectrum

Transmission Infrared (IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 6Se3yFNPcyX
Name FOSTA NYLON 512 - Controlled Pyrolyzate (Condensed Phase)
Source of Sample Foster Grant Company, Inc.
Chemical Description MEDIUM VISCOSITY, GENERAL PURPOSE INJECTION MOLDING NYLON
Copyright Copyright © 1980, 1981-2024 John Wiley & Sons, Inc. All Rights Reserved.
Density (Specific Gravity)= (23C) (D792) 1.14
Elongation (FAIL) (D638) 30%
Melting Point (D789) 420F
Sample Procedure The pyrolysis technique is commonly used in the infrared identification of polymers and results in spectra of both the volatile and non-volatile pyrolyzed fractions the polymer under investigation. It can be used by researchers to identify principal polymer types. This record contains the non-volatile (Condensed Phase) IR spectrum resulting from the pyrolysis of FOSTA NYLON 512. The IR spectrum of the volatile (Vapor Phase) fraction resulting from the pyrolysis of FOSTA NYLON 512 is FOSTA NYLON 512 - Controlled Pyrolyzate (Vapor Phase).
Technique Condensed Phase
Tensile Strength (YIELD) (D638) 12500 PSI