For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
3-Chloro-5-(trifluoromethyl)benzoic acid
SpectraBase Compound ID 6OE5FHMu2ed
InChI InChI=1S/C8H4ClF3O2/c9-6-2-4(7(13)14)1-5(3-6)8(10,11)12/h1-3H,(H,13,14)
InChIKey IDLOGBMWOUINGG-UHFFFAOYSA-N
Mol Weight 224.57 g/mol
Molecular Formula C8H4ClF3O2
Exact Mass 223.985192 g/mol

Raman Spectrum

Raman Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 6Q7od5II7V1
Name 3-Chloro-5-(trifluoromethyl)benzoic acid
Source of Sample Alfa Aesar, Thermo Fisher Scientific
Catalog Number H26399
Lot Number 10159435
Acquisition Mode double sided, forward-backward
Actual Signal Gain 2
Additional Data Treatment 1
Aperture Setting 2.5 mm
Apodization Function Norton-Beer, medium
Backward Peak Amplitude 2331
Backward Peak Location 28687
Beam Splitter Setting Quartz
CAS Registry Number 53985-49-2
Calibration Lamp Spectrum Correction.0
Container ID C-009881
Copyright Copyright © 2017-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 15 s
Detector Setting LN-Ge Diode [Internal Pos.2]
End Frequency Limit for File 9394.3
External Analog Signals Off
External Synchronization Off
Focal Length 100
Formula C8H4ClF3O2
Frequency of First Point 3597.79 cm⁻¹
Frequency of Last Point -1.31092 cm⁻¹
High Folding Limit 31596.8
High Frequency Limit 30000 cm⁻¹
High Pass Filter 1
InChI InChI=1S/C8H4ClF3O2/c9-6-2-4(7(13)14)1-5(3-6)8(10,11)12/h1-3H,(H,13,14)
InChIKey IDLOGBMWOUINGG-UHFFFAOYSA-N
Instrument Name Bruker MultiRAM Stand Alone FT-Raman Spectrometer
Laser Wavenumber 15798.4 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 5
Measurement Channel Raman Compartment
Molecular Weight 224.566 g/mol
Non Linearity Correction 0
Number of Points 7466
Number of Sample Scans 174
Optical Filter Setting Open
Peak Amplitude -2281
Peak Location 28693
Phase Correction Mode power spectrum
Phase Resolution 1
Physical State Solid
Preamplifier Gain 0
Purity 97%
Raman Background Corrected Yes
Raman Corrections Referenced to internal light source; Scattering corrected
Raman Laser Source Nd:YAG
Raman Scattering Corrected Yes
Resolution 2
SKU H26399-1G
SMILES OC(c1cc(cc(c1)Cl)C(F)(F)F)=O
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 2
Scan Time 0 s
Scanner Velocity 5 kHz
Signal Gain, Sample 2
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 5794.76 cm⁻¹
Technique FT-Raman
Zero Filling Factor 4