For citations & permissions, please see: Citations & Permissions - Wiley Science Solutions*

*Links on SpectraBase are not permalinks.
2-Methylbenzhydryl chloride
SpectraBase Compound ID G0o8wi9Qpgh
InChI InChI=1S/C14H13Cl/c1-11-7-5-6-10-13(11)14(15)12-8-3-2-4-9-12/h2-10,14H,1H3
InChIKey VTZTUKIBJQCCMO-UHFFFAOYSA-N
Mol Weight 216.71 g/mol
Molecular Formula C14H13Cl
Exact Mass 216.070578 g/mol

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

Attenuated Total Reflectance Infrared (ATR-IR) Spectrum

View the Full Spectrum for FREE!

The full spectrum can only be viewed using a FREE account.

SpectraBase Spectrum ID 6DYWSpnWvg5
Name 2-Methylbenzhydryl chloride
Source of Sample TCI Chemicals India Pvt. Ltd.
Catalog Number M2211
Lot Number YHKPC-KS
Accessory DuraSample IR #145404C7
Acquisition Mode double sided, forward-backward
Actual Signal Gain 16
Actual Signal Gain 2nd Channel 1
Additional Data Treatment 1
Analog Signal 1 0.270596
Analog Signal 2 0
Aperture Setting 6 mm
Apodization Function Norton-Beer, medium
Background Measurement Channel Sample Compartment
Background Peak Amplitude 2nd Channel 1
Background Peak Location 2nd Channel 1
Background Rotations 32
Background Scans 32
Background Scans or Time Scans
Backward Peak Amplitude -1492
Backward Peak Location 7352
Beam Splitter Setting KBr
CAS Registry Number 41870-52-4
Color Properties White
Container ID C-010106
Copyright Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved.
Data Point Format 1
Delay Before Measurement 1 s
Detector Setting RT-DLaTGS [Internal]
End Frequency Limit for File 340
External Synchronization Off
Focal Length 100
Formula C14H13Cl
Frequency of First Point 3998.29 cm⁻¹
Frequency of Last Point 339.459 cm⁻¹
High Folding Limit 15800.3
High Frequency Limit 8000 cm⁻¹
High Pass Filter 0
InChI InChI=1S/C14H13Cl/c1-11-7-5-6-10-13(11)14(15)12-8-3-2-4-9-12/h2-10,14H,1H3
InChIKey VTZTUKIBJQCCMO-UHFFFAOYSA-N
Instrument Name Bruker Tensor 27 FT-IR
Laser Wavenumber 15800.3 cm⁻¹
Low Folding Limit 0
Low Frequency Limit 0
Low Pass Filter 10
Measurement Channel Sample Compartment
Molecular Weight 216.711 g/mol
Non Linearity Correction 0
Number of Points 3795
Number of Sample Scans 32
Optical Filter Setting Open
Peak Amplitude -1527
Peak Amplitude 2nd Channel 1
Peak Location 7383
Peak Location 2nd Channel 1
Phase Correction Mode Mertz
Phase Resolution 8
Physical State Solid
Preamplifier Gain 3
Preamplifier Gain Background 0
Purity >98.0%
Relative Humidity Interferometer 20 %
Resolution 4
SKU M2211-5G
SMILES c1c(c(ccc1)C)C(c1ccccc1)Cl
Sample Comments Sample ground at metal edge of ATR
Sample Rotations 32
Sample Scans or Time Scans
Sample Spacing Divisor 1
Sample Spacing Multiplicator 1
Scan Time 27.31 s
Scanner Temperature 29.3 °C
Scanner Velocity 10 kHz
Signal Gain, Background automatic
Signal Gain, Sample automatic
Source of Spectrum Bio-Rad Laboratories, Inc.
Start Frequency Limit for File 4000 cm⁻¹
Synonyms 2-(α-Chlorobenzyl)toluene; Chloro(2-methylphenyl)phenylmethane
Technique ATR-Neat
Zero Filling Factor 4